Investigação, Desenvolvimento e Inovação · Aceite pela Entidade

Novos sitemas óticos biomiméticos para o seguimento de biomarcadores de cancro

INSTITUTO SUPERIOR DE ENGENHARIA DO PORTO

Fondo aprobado
167.443,20 €
Fondo ejecutado
0,00 €
Fondo pagado
0,00 €

Esta ficha organiza los campos que Portugal 2030 publica sobre la operación: financiación aprobada, ejecución administrativa, encuadre y territorio. El mérito de la candidatura y los resultados sobre el terreno no constan en esta fuente.

COMPETE2030-FEDER-00752500

Finalidad de la operación

The main objective is to develop a portable device for direct optical reading with restricted access to healthcare professionals, to monitor the levels of five biomarkers associated with pancreatic cancer. The final response will be semi-quantitative, based on comparison with a graduated color scale, using reading under ultraviolet light available in accredited fluorescent reading software for this purpose. Ten objectives are proposed as follows: 1. Monitor and track cancer biomarker levels to predict disease recurrence in patients who suffer or have suffered from this health condition. 2. Develop portable devices for direct reading as a diagnostic means, allowing patients to monitor their own biomarker levels in real time. This involves the creation of simple fluorometric sensors based on…

Leer la descripción publicada íntegra

The main objective is to develop a portable device for direct optical reading with restricted access to healthcare professionals, to monitor the levels of five biomarkers associated with pancreatic cancer. The final response will be semi-quantitative, based on comparison with a graduated color scale, using reading under ultraviolet light available in accredited fluorescent reading software for this purpose. Ten objectives are proposed as follows: 1. Monitor and track cancer biomarker levels to predict disease recurrence in patients who suffer or have suffered from this health condition. 2. Develop portable devices for direct reading as a diagnostic means, allowing patients to monitor their own biomarker levels in real time. This involves the creation of simple fluorometric sensors based on quantum dots and carbon dots, which exhibit RGB color changes for visual quantification of cancer biomarkers under ultraviolet light. The colorimetric fluorescent paper test will allow naked-eye observation of fluorescence color variations when a human physiological sample containing the target analyte is added. 3. Develop a dual fluorescent paper sensor, which includes an internal reference system and a sensor system, offering flexibility and adequate sensitivity. 4. Innovate by printing the dual sensor on paper, which will exhibit an initial fluorescent color change when a human sample containing the target analyte is added, with the final result read on a colorimetric scale adjusted for each analyte. 5. Integrate the paper sensor with a software platform that will function as a color recognition application, reading the RGB coordinates of the color generated by the sample in real time and on the test paper. The sensor is designed to detect multiple cancer biomarkers simultaneously when the tested paper is irradiated under 365 nm UV light. 6. Read the signal generated in a semi-quantitative format, comparing the resulting color with the color associated with the range of values assigned on a paper scale used as a reference for that analyte. 7. Collaborate with an external SA company to develop an electronic diagnostic device based on open-source software and hardware, aiming to create a low-cost solution. 8. Use the proof-of-concept device generated to attract venture investors, protect intellectual property, and initiate a spin-off project to optimize the device and advance to commercialization. 9. Validate the referential RGB colorimetric scale in semi-quantitative results by collecting samples from symptomatic individuals of the cancer under study and asymptomatic individuals at risk of developing the disease, and evaluating the results by this scale for each biomarker. 10. Compare the RGB colors of the reference scale with the results obtained from certified laboratory tests for these biomarkers, in order to create an algorithm correlating the semi-quantitative values given by the RGB scale with the values obtained from certified tests.

Cómo se encuadra la operación

Programa
Programa Inovação e Transição Digital
Fondo
Fundo Europeu de Desenvolvimento Regional
Objetivo estratégico
+ Inteligente
Objetivo específico
Reforçar a investigação, inovação e adoção de tecnologias avançadas.
Área temática
Investigação, Desenvolvimento e Inovação
Actividad económica
Atividades de investigação
Modalidad
Subvenção
Tasa de cofinanciación
85%

Distribución territorial publicada

PortoÁrea Metropolitana do Porto · Norte
100% de la localización

Localización observada en el archivo del 31 de octubre de 2026.

Calendario publicado

Inicio previsto
1 de febrero de 2026
Inicio efectivo
No indicada
Conclusión prevista
1 de enero de 2029
Conclusión efectiva
No indicada

Fuente oficial y fechas de corte

Operación e importes: 31 de octubre de 2026. Localización: 31 de octubre de 2026.

Consultar el portal oficial de Portugal 2030 ↗Capturas validadas por SHA-256; fuente verificada el 18 de noviembre de 2026.